Concept
Metal ligand parameters in the water column
URI | http://vocab.nerc.ac.uk/collection/P02/current/ZNLG/ | |
---|---|---|
Within Vocab | SeaDataNet Parameter Discovery Vocabulary | |
Alternative Labels | WC_MetalLigand | |
Definition | Parameters concerned with the complexation of metals as ligands in the water column | |
Date | 2004-08-11T16:06:28 | |
Identifier | SDN:P02::ZNLG | |
Note | accepted | |
Has Current Version | 1 | |
version | 1 | |
inScheme | http://vocab.nerc.ac.uk/scheme/EDMED_DCAT_THEMES/current/ | |
Broader | D01:D0100001 | Parameters |
L19:005 | theme | |
P05:014 | oceans | |
P22:28 | Oceanographic geographical features | |
L04:L04001 | water body | |
P04:G694 | EARTH SCIENCE > Hydrosphere > Water Quality/Water Chemistry > Trace Metals | |
P03:C045 | Other inorganic chemical measurements | |
P03:C035 | Metal and metalloid concentrations | |
P03:C050 | Other organic chemical measurements | |
Narrower | P01:LCIFECL2 | Log ligand binding strength 95 per cent confidence interval of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry |
P01:SDFLCVD5 | Log ligand binding strength standard deviation of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LOGCUCS5 | Log ligand binding strength of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:LTM01414 | Log ligand binding strength lower uncertainty of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry | |
P01:LOGFECL2 | Log ligand binding strength of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LOG4SDL1 | Log ligand binding strength standard deviation of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry | |
P01:SDLO4EL2 | Log ligand binding strength standard deviation of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry | |
P01:LTM00990 | Log ligand binding strength lower uncertainty of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry | |
P01:LOGFECL1 | Log ligand binding strength of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LTM01919 | Log ligand binding strength lower uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry | |
P01:LOGCUCL1 | Log ligand binding strength of copper-complexing organic ligands (of the stronger dissolved copper-binding ligand (L1)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:SDLO4EL3 | Log ligand binding strength standard deviation of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L3)) in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry | |
P01:LOGFLEL2 | Log ligand binding strength lower uncertainty of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:SDFLCVDN | Log ligand binding strength standard deviation of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <10**6 Dalton phase] by filtration and cathodic stripping voltammetry | |
P01:LCIFECL1 | Log ligand binding strength 95 per cent confidence interval of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:ZNLSCVZZ | Log ligand binding strength of zinc-complexing organic ligands {Zn_org_ligands} in the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:FELSCVE6 | Log ligand binding strength standard error of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:SDLFCUE6 | Log ligand binding strength upper uncertainty of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LOGFECL3 | Log ligand binding strength of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L3)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LTM01010 | Log ligand binding strength upper uncertainty of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry | |
P01:COLGCVZZ | Log ligand binding strength of cobalt-complexing organic ligands {Co_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:FELSCVUL | Log ligand binding strength of iron-complexing organic ligands (iron-complexing, upper limit calculated from unfiltered iron concentration) in the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:LOGFSDL1 | Log ligand binding strength standard deviation of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LTM02525 | Log ligand binding strength upper uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry | |
P01:LLBSEDL2 | Log ligand binding strength lower uncertainty of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:SDFLCVZZ | Log ligand binding strength standard deviation of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:SDFLCVUL | Log ligand binding strength standard deviation of iron-complexing organic ligands (iron-complexing, upper limit calculated from unfiltered iron concentration) in the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:SDZLCVZZ | Log ligand binding strength standard deviation of zinc-complexing organic ligands {Zn_org_ligands} in the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:LOG4ECL3 | Log ligand binding strength of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L3)) in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry | |
P01:FELSCVZZ | Log ligand binding strength of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:LLBSERL1 | Log ligand binding strength upper uncertainty of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LTM00330 | Log ligand binding strength of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry | |
P01:LLBSEDL1 | Log ligand binding strength lower uncertainty of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LTM02424 | Log ligand binding strength lower uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry | |
P01:LTM02929 | Log ligand binding strength lower uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry | |
P01:LLBSERL2 | Log ligand binding strength upper uncertainty of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:SDLFCLE6 | Log ligand binding strength lower uncertainty of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LTM03030 | Log ligand binding strength upper uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry | |
P01:FELSCVLL | Log ligand binding strength of iron-complexing organic ligands (iron-complexing, lower limit calculated from filtered (<0.2um) Fe) in the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:SDLOFEL2 | Log ligand binding strength standard deviation of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LCIFECL3 | Log ligand binding strength 95 per cent confidence interval of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L3)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:SDFLCVLL | Log ligand binding strength standard deviation of iron-complexing organic ligands (iron-complexing, lower limit calculated from filtered (<0.2um) Fe) in the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:FELSCVDN | Log ligand binding strength of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <10**6 Dalton phase] by filtration and cathodic stripping voltammetry | |
P01:FELSCVD5 | Log ligand binding strength of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:SDCOCVZZ | Log ligand binding strength standard deviation of cobalt-complexing organic ligands {Co_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LOGFUEL2 | Log ligand binding strength upper uncertainty of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LTM01818 | Log ligand binding strength of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry | |
P01:SDLOFEL3 | Log ligand binding strength standard deviation of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L3)) in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LTM00880 | Log ligand binding strength of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry | |
P01:LTM02828 | Log ligand binding strength of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry | |
P01:LOG4ECL1 | Log ligand binding strength of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry | |
P01:LTM01313 | Log ligand binding strength of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry | |
P01:SDLOGCU7 | Log ligand binding strength standard deviation of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:LTM02323 | Log ligand binding strength of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry | |
P01:LTM01515 | Log ligand binding strength upper uncertainty of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry | |
P01:LOG4ECL2 | Log ligand binding strength of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) in the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry | |
P01:LTM00550 | Log ligand binding strength upper uncertainty of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry | |
P01:LTM02020 | Log ligand binding strength upper uncertainty of copper-complexing organic ligands {Cu_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry | |
P01:LTM00440 | Log ligand binding strength lower uncertainty of iron-complexing organic ligands {Fe_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry | |
P01:SDLGCODX | Concentration standard deviation of cobalt-complexing organic ligands {Co_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:CTM02626 | Concentration of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry | |
P01:LG4ECSL2 | Concentration of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry | |
P01:COLGCVDX | Concentration of organic ligand-bound cobalt {ligand-complexed_Co CAS 7440-48-4} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LGFECSL1 | Concentration of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LG4ECSL3 | Concentration of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L3)) per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry | |
P01:LGZNCVDX | Concentration of zinc-complexing organic ligands {Zn_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:FENHGSD1 | Concentration standard deviation of ferrioxamine G per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and high performance liquid chromatography - inductively coupled plasma mass spectrometry | |
P01:LGFECVLL | Concentration of iron-complexing organic ligands (iron-complexing, lower limit calculated from filtered (<0.2um) Fe) per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:DFFELXX1 | Concentration of iron-complexing organic ligands (excess, non-complexed) per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:LGFECVDN | Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <10**6 Dalton phase] by filtration and cathodic stripping voltammetry | |
P01:CTM02727 | Concentration standard error of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry | |
P01:FENHGMS1 | Concentration of ferrioxamine G per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and high performance liquid chromatography - inductively coupled plasma mass spectrometry | |
P01:SDLFCVLL | Concentration standard deviation of iron-complexing organic ligands (iron-complexing, lower limit calculated from filtered (<0.2um) Fe) per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:LGCOCVDX | Concentration of cobalt-complexing organic ligands {Co_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:CTM01111 | Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry | |
P01:SDLFCVDX | Concentration standard deviation of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:CTM00770 | Concentration standard error of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry | |
P01:DCOPCVDX | Concentration of cobalt (dissolved) (ligand complexed) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LG4ESDL1 | Concentration standard deviation of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry | |
P01:LGCUCSL1 | Concentration of copper-complexing organic ligands (of the stronger dissolved copper-binding ligand (L1)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LGFESDL2 | Concentration standard deviation of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LGFECVD5 | Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:ZNLGCVDX | Concentration of organic ligand-bound zinc {ligand-complexed_Zn CAS 7440-66-6} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:LGFESEL1 | Concentration standard error of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LG4ESDL2 | Concentration standard deviation of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry | |
P01:CTM01717 | Concentration standard error of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry | |
P01:LGFESDL3 | Concentration standard deviation of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L3)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:FENHESD1 | Concentration standard deviation of ferrioxamine E {hydroxamate siderophore CAS 20008-20-2} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and high performance liquid chromatography - inductively coupled plasma mass spectrometry | |
P01:LGCUSDA5 | Concentration standard deviation of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:LGFESEL2 | Concentration standard error of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LG4ESDL3 | Concentration standard deviation of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L3)) per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry | |
P01:SDLFCVE6 | Concentration standard error of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:SDLZCVDX | Concentration standard deviation of zinc-complexing organic ligands {Zn_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:CTM02121 | Concentration of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry | |
P01:CTM01212 | Concentration standard error of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry | |
P01:FENHEMS1 | Concentration of ferrioxamine E {hydroxamate siderophore CAS 20008-20-2} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and high performance liquid chromatography - inductively coupled plasma mass spectrometry | |
P01:CTM00660 | Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry | |
P01:LGXSFEDN | Concentration of iron-complexing organic ligands (excess, non-complexed) per unit volume of the water body [dissolved plus reactive particulate <10**6 Dalton phase] by filtration and cathodic stripping voltammetry | |
P01:LGFECVDX | Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:CTM01616 | Concentration of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry | |
P01:LGFECSL2 | Concentration of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LGFECIL1 | Concentration 95 per cent confidence interval of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:CTM00220 | Concentration standard error of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry | |
P01:LGXSFED5 | Concentration of iron-complexing organic ligands (excess, non-complexed) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LGFECVUL | Concentration of iron-complexing organic ligands (iron-complexing, upper limit calculated from unfiltered iron concentration) per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:LGFECSL3 | Concentration of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L3)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:LGFECIL2 | Concentration 95 per cent confidence interval of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L2)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:CTM02222 | Concentration standard error of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry | |
P01:FELGCVDX | Concentration of iron (ligand complexed) per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:LGCUCSV5 | Concentration of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
P01:SDLFCVDN | Concentration standard deviation of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <10**6 Dalton phase] by filtration and cathodic stripping voltammetry | |
P01:LGFECIL3 | Concentration 95 per cent confidence interval of iron-complexing organic ligands (of the weaker dissolved iron-binding ligand (L3)) per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:CTM00110 | Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry | |
P01:LG4ECSL1 | Concentration of iron-complexing organic ligands (of the stronger dissolved iron-binding ligand (L1)) per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration and cathodic stripping voltammetry | |
P01:SDLFCVD5 | Concentration standard deviation of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry | |
P01:SDLFCVUL | Concentration standard deviation of iron-complexing organic ligands (iron-complexing, upper limit calculated from unfiltered iron concentration) per unit volume of the water body [dissolved plus reactive particulate phase] by cathodic stripping voltammetry | |
Related | P04:G911 | EARTH SCIENCE > Oceans > Ocean Chemistry > Trace Elements |
P64:G911 | EARTH SCIENCE > Oceans > Ocean Chemistry > Trace Elements | |
P64:G891 | EARTH SCIENCE > Oceans > Ocean Chemistry > Marine Geochemistry | |
P04:G891 | EARTH SCIENCE > Oceans > Ocean Chemistry > Marine Geochemistry |
Alternate Formats
Other formats for this page:
RDF/XML Turtle JSON-LDAlternate Profiles
Other views of this page:
Alternate Profiles ?Different Media Types (HTML, text, RDF, JSON etc.) and different information model views, profiles, are available for this resource.