CONFIG_MaxDelayBeforeCycleStart_minutes
URI | http://vocab.nerc.ac.uk/collection/R18/current/CC00107/ | |
---|---|---|
Within Vocab | Argo configuration parameter names | |
Alternative Labels | Core Config 107 - Optional | |
Definition | The maximum extra time a float can stay on the surface after transmitting. This feature is used for SOLOII floats to try and make them stay in a particular area, e.g. near the equator for equatorial floats. If a float is drifting at the surface and moving in the direction we want, we turn the feature on to keep it drifting at the surface in a favourable direction. If the float is moving in a direction we don't want, then we turn this feature off, so the float dives immediately. Changeable via 2-way communications. | |
Date | 2023-05-02T16:34:05 | |
Identifier | SDN:R18::CC00107 | |
Note | accepted | |
Has Current Version | 1 | |
version | 1 |