CONFIG_IceDetectionConnectionTimeOut_minutes
URI | http://vocab.nerc.ac.uk/collection/R18/current/CC00072/1/ | |
---|---|---|
Within Vocab | Argo configuration parameter names | |
Alternative Labels | Core Config 72 - Optional | |
Definition | Similar to CONFIG_ConnectionTimeOut_minutes but for the first telemetry session of a float in ice detection mode(i.e. in ice detection mode the float reduces the timeout of the first Iridium connection: if the first connection fails the cycle is aborted (ice probably present) but if the first connection succeeds (waters free of ice) the float switches to the nominal timeout (CONFIG_ConnectionTimeOut_minutes) for the following transmissions of the current cycle). | |
Date | 2023-05-02T16:34:05 | |
Identifier | SDN:R18::CC00072 | |
Note | accepted | |
Is Version Of | CC00072 | |
version | 1 |
Alternate Formats
Other formats for this page:
RDF/XML Turtle JSON-LDAlternate Profiles
Other views of this page:
Alternate Profiles ?Different Media Types (HTML, text, RDF, JSON etc.) and different information model views, profiles, are available for this resource.
NVS html view ? Default NVS html view.