| URI | 
          http://vocab.nerc.ac.uk/collection/S06/current/S0600183/1/ | 
        
        
          | Within Vocab | 
          BODC parameter semantic model parameter entity names | 
        
        
        
          | Alternative Labels | 
          
            
              
            
           | 
        
        
        
          | Definition | 
          The raw voltage output of a measuring device before conversion to engineering units. | 
        
        
          | Date | 
          2018-07-06T12:58:46 | 
        
        
        
          
            
              | Identifier | 
              SDN:S06::S0600183 | 
            
          
            
              | Note | 
              accepted | 
            
          
        
        
          
            
              | Is Version Of | 
              S0600183 | 
            
          
        
        
        
        
          
            
              | version | 
              1 | 
            
          
        
        
        
        
            
            | 
              Broader
             | 
			
				
					
					
                S01:S014 | 
                parameter entity | 
             | 
					
				
				
					
				
			
        
            
            | 
              Narrower
             | 
			
				
					
					
						
							| 
                 | P01:SVLTA434 | 
                Raw signal (voltage) of instrument output (434nm wavelength absorbance) by spectrophotometry | 
             | 
						
					
						
							| 
                 | P01:SVLTA578 | 
                Raw signal (voltage) of instrument output (578nm wavelength absorbance) by spectrophotometry | 
             | 
						
					
						
							| 
                 | P01:AVLTOPTX | 
                Raw signal (voltage) of instrument output (ambient light) by optode | 
             | 
						
					
						
							| 
                 | P01:OXYCOPVB | 
                Raw signal (voltage) of instrument output (blue light wavelength excitation) by optode | 
             | 
						
					
						
							| 
                 | P01:TVLTOT01 | 
                Raw signal (voltage) of instrument output (optical cell) by temperature sensor | 
             | 
						
					
						
							| 
                 | P01:TVLTOT02 | 
                Raw signal (voltage) of instrument output (optical cell) by temperature sensor (second sensor) | 
             | 
						
					
						
							| 
                 | P01:OXYCOPVR | 
                Raw signal (voltage) of instrument output (red light wavelength excitation) by optode | 
             | 
						
					
						
							| 
                 | P01:TVLTPR01 | 
                Raw signal (voltage) of instrument output by 1m path length red light transmissometer | 
             | 
						
					
						
							| 
                 | P01:TVLTPZ01 | 
                Raw signal (voltage) of instrument output by 1m path length transmissometer | 
             | 
						
					
						
							| 
                 | P01:TVLTCR01 | 
                Raw signal (voltage) of instrument output by 20cm path length red light transmissometer | 
             | 
						
					
						
							| 
                 | P01:TVLTCZ01 | 
                Raw signal (voltage) of instrument output by 20cm path length transmissometer | 
             | 
						
					
						
							| 
                 | P01:TVLTDR01 | 
                Raw signal (voltage) of instrument output by 25cm path length red light transmissometer | 
             | 
						
					
						
							| 
                 | P01:TVLTDZ01 | 
                Raw signal (voltage) of instrument output by 25cm path length transmissometer | 
             | 
						
					
						
							| 
                 | P01:NH4VLTZZ | 
                Raw signal (voltage) of instrument output by ammonia analysis system | 
             | 
						
					
						
							| 
                 | P01:NVLTAQ01 | 
                Raw signal (voltage) of instrument output by Aquatracka nephelometer | 
             | 
						
					
						
							| 
                 | P01:LVLTBD01 | 
                Raw signal (voltage) of instrument output by Biospherical Instruments 2-pi PAR downwelling light meter | 
             | 
						
					
						
							| 
                 | P01:LVLTBU01 | 
                Raw signal (voltage) of instrument output by Biospherical Instruments 2-pi PAR upwelling light meter | 
             | 
						
					
						
							| 
                 | P01:LVLTLD01 | 
                Raw signal (voltage) of instrument output by cosine-collector downwelling PAR radiometer | 
             | 
						
					
						
							| 
                 | P01:LVLTLU01 | 
                Raw signal (voltage) of instrument output by cosine-collector upwelling PAR radiometer | 
             | 
						
					
						
							| 
                 | P01:NVLTEP01 | 
                Raw signal (voltage) of instrument output by EMP-2000 optical backscatter sensor | 
             | 
						
					
						
							| 
                 | P01:FVLTAQ01 | 
                Raw signal (voltage) of instrument output by in-situ Aquatracka chlorophyll fluorometer | 
             | 
						
					
						
							| 
                 | P01:FVLTZZ01 | 
                Raw signal (voltage) of instrument output by in-situ chlorophyll fluorometer | 
             | 
						
					
						
							| 
                 | P01:OXYVLTN1 | 
                Raw signal (voltage) of instrument output by in-situ microelectrode | 
             | 
						
					
						
							| 
                 | P01:OXYVLTN2 | 
                Raw signal (voltage) of instrument output by in-situ microelectrode (second sensor) | 
             | 
						
					
						
							| 
                 | P01:TCNTOPTT | 
                Raw signal (voltage) of instrument output by in-situ thermistor | 
             | 
						
					
						
							| 
                 | P01:N03UVVLT | 
                Raw signal (voltage) of instrument output by in-situ UV nitrate analyser | 
             | 
						
					
						
							| 
                 | P01:FVLTCDOM | 
                Raw signal (voltage) of instrument output by linear-response CDOM fluorometer | 
             | 
						
					
						
							| 
                 | P01:FVLTWS01 | 
                Raw signal (voltage) of instrument output by linear-response chlorophyll fluorometer | 
             | 
						
					
						
							| 
                 | P01:FVLTPHCN | 
                Raw signal (voltage) of instrument output by linear-response phycocyanin fluorometer | 
             | 
						
					
						
							| 
                 | P01:FVLTPELN | 
                Raw signal (voltage) of instrument output by linear-response phycoerythrin fluorometer | 
             | 
						
					
						
							| 
                 | P01:NVLTLS01 | 
                Raw signal (voltage) of instrument output by LISST scatterometer | 
             | 
						
					
						
							| 
                 | P01:NO3VLTZZ | 
                Raw signal (voltage) of instrument output by nitrate analysis system | 
             | 
						
					
						
							| 
                 | P01:NO2VLTZZ | 
                Raw signal (voltage) of instrument output by nitrite analysis system | 
             | 
						
					
						
							| 
                 | P01:OXYOCPVL | 
                Raw signal (voltage) of instrument output by oxygen sensor | 
             | 
						
					
						
							| 
                 | P01:OXYOCPV2 | 
                Raw signal (voltage) of instrument output by oxygen sensor (second sensor) | 
             | 
						
					
						
							| 
                 | P01:PO4VLTZZ | 
                Raw signal (voltage) of instrument output by phosphate analysis system | 
             | 
						
					
						
							| 
                 | P01:LVLTPD01 | 
                Raw signal (voltage) of instrument output by PML/Chelsea Instruments 2-pi PAR downwelling light meter | 
             | 
						
					
						
							| 
                 | P01:LVLTPU01 | 
                Raw signal (voltage) of instrument output by PML/Chelsea Instruments 2-pi PAR upwelling light meter | 
             | 
						
					
						
							| 
                 | P01:DVLTRPSD | 
                Raw signal (voltage) of instrument output by port-mounted PAR cosine-collector radiometer | 
             | 
						
					
						
							| 
                 | P01:CVLTRP01 | 
                Raw signal (voltage) of instrument output by port-mounted pyranometer | 
             | 
						
					
						
							| 
                 | P01:TVLTZR01 | 
                Raw signal (voltage) of instrument output by red light transmissometer | 
             | 
						
					
						
							| 
                 | P01:NVLTSC01 | 
                Raw signal (voltage) of instrument output by SCUFA turbidity meter | 
             | 
						
					
						
							| 
                 | P01:NVLTSP01 | 
                Raw signal (voltage) of instrument output by SeaPoint turbidity meter | 
             | 
						
					
						
							| 
                 | P01:NVLTST01 | 
                Raw signal (voltage) of instrument output by SeaTech light backscatter nephelometer (LBSS) | 
             | 
						
					
						
							| 
                 | P01:SIOVLTZZ | 
                Raw signal (voltage) of instrument output by silicate analysis system | 
             | 
						
					
						
							| 
                 | P01:DVLTRSSD | 
                Raw signal (voltage) of instrument output by starboard-mounted PAR cosine-collector radiometer | 
             | 
						
					
						
							| 
                 | P01:CVLTRS01 | 
                Raw signal (voltage) of instrument output by starboard-mounted pyranometer | 
             | 
						
					
						
							| 
                 | P01:SUVVV220 | 
                Raw signal (voltage) of instrument output by SUV-6 in-situ nitrate analyser at 220nm | 
             | 
						
					
						
							| 
                 | P01:SUVVV235 | 
                Raw signal (voltage) of instrument output by SUV-6 in-situ nitrate analyser at 235nm | 
             | 
						
					
						
							| 
                 | P01:SUVVV250 | 
                Raw signal (voltage) of instrument output by SUV-6 in-situ nitrate analyser at 250nm | 
             | 
						
					
						
							| 
                 | P01:RAWVLT3D | 
                Raw signal (voltage) of instrument output by three-dimensional seismic survey array | 
             | 
						
					
						
							| 
                 | P01:TVLTZZ01 | 
                Raw signal (voltage) of instrument output by transmissometer | 
             | 
						
					
						
							| 
                 | P01:NVLTSC11 | 
                Raw signal (voltage) of instrument output by turbidity meter | 
             | 
						
					
						
							| 
                 | P01:RAWVLT2D | 
                Raw signal (voltage) of instrument output by two-dimensional seismic survey array | 
             | 
						
					
						
							| 
                 | P01:NVLTWL01 | 
                Raw signal (voltage) of instrument output by WET Labs optical backscatter meter | 
             | 
						
					
						
							| 
                 | P01:NVLTWG01 | 
                Raw signal (voltage) of instrument output by WET Labs optical backscatter meter (green LED) | 
             | 
						
					
						
							| 
                 | P01:NVLTWR01 | 
                Raw signal (voltage) of instrument output by WET Labs optical backscatter meter (red LED) | 
             | 
						
					
						
							| 
                 | P01:UU01440V | 
                Raw signal (voltage) of instrument output in the water body by cosine-collector upwelling 440nm radiometer | 
             | 
						
					
						
							| 
                 | P01:UU01490V | 
                Raw signal (voltage) of instrument output in the water body by cosine-collector upwelling 490nm radiometer | 
             | 
						
					
						
							| 
                 | P01:UU01570V | 
                Raw signal (voltage) of instrument output in the water body by cosine-collector upwelling 570nm radiometer | 
             | 
						
					
						
							| 
                 | P01:UU01670V | 
                Raw signal (voltage) of instrument output in the water body by cosine-collector upwelling 670nm radiometer | 
             | 
						
					
						
							| 
                 | P01:TVLTSR01 | 
                Raw signal (voltage) of instrument output water body by 10cm path length red light transmissometer | 
             | 
						
					
						
							| 
                 | P01:TVSDCR01 | 
                Raw signal (voltage) standard deviation of instrument output by 20cm path length red light transmissometer | 
             | 
						
					
						
							| 
                 | P01:SVLTBD01 | 
                Raw signal (voltage) standard deviation of instrument output by Biospherical Instruments 2-pi PAR downwelling light meter | 
             | 
						
					
						
							| 
                 | P01:SVLTBU01 | 
                Raw signal (voltage) standard deviation of instrument output by Biospherical Instruments 2-pi PAR upwelling light meter | 
             | 
						
					
						
							| 
                 | P01:LVSDLD01 | 
                Raw signal (voltage) standard deviation of instrument output by cosine-collector downwelling PAR radiometer | 
             | 
						
					
						
							| 
                 | P01:LVLTLUSD | 
                Raw signal (voltage) standard deviation of instrument output by cosine-collector upwelling PAR radiometer | 
             | 
						
					
						
							| 
                 | P01:FVLTQSD1 | 
                Raw signal (voltage) standard deviation of instrument output by in-situ Aquatracka chlorophyll fluorometer | 
             | 
						
					
						
							| 
                 | P01:OXVLTSD1 | 
                Raw signal (voltage) standard deviation of instrument output by in-situ microelectrode | 
             | 
						
					
						
							| 
                 | P01:NO3UVSSD | 
                Raw signal (voltage) standard deviation of instrument output by in-situ UV nitrate analyser | 
             | 
						
					
						
							| 
                 | P01:FVSDWS01 | 
                Raw signal (voltage) standard deviation of instrument output by linear-response chlorophyll fluorometer | 
             | 
						
					
						
							| 
                 | P01:NVLTLSD1 | 
                Raw signal (voltage) standard deviation of instrument output by LISST scatterometer | 
             | 
						
					
						
							| 
                 | P01:OXYRVSD1 | 
                Raw signal (voltage) standard deviation of instrument output by oxygen sensor | 
             | 
						
					
						
							| 
                 | P01:OXYRVSD2 | 
                Raw signal (voltage) standard deviation of instrument output by oxygen sensor (second sensor) | 
             | 
						
					
						
							| 
                 | P01:LVSDPD01 | 
                Raw signal (voltage) standard deviation of instrument output by PML/Chelsea Instruments 2-pi PAR downwelling light meter | 
             | 
						
					
						
							| 
                 | P01:LVSDPU01 | 
                Raw signal (voltage) standard deviation of instrument output by PML/Chelsea Instruments 2-pi PAR upwelling light meter | 
             | 
						
					
						
							| 
                 | P01:TVLTSD01 | 
                Raw signal (voltage) standard deviation of instrument output by transmissometer | 
             | 
						
					
						
							| 
                 | P01:NVLTSD01 | 
                Raw signal (voltage) standard deviation of instrument output by WET Labs optical backscatter meter | 
             | 
						
					
						
							| 
                 | P01:NVSDWG01 | 
                Raw signal (voltage) standard deviation of instrument output by WET Labs optical backscatter meter (green LED) | 
             | 
						
					
						
							| 
                 | P01:NVSDWR01 | 
                Raw signal (voltage) standard deviation of instrument output by WET Labs optical backscatter meter (red LED) | 
             | 
						
					
						
							| 
                 | P01:TVSDSR01 | 
                Raw signal (voltage) standard deviation of instrument output water body by 10cm path length red light transmissometer | 
             | 
						
					
						
							| 
                 | P01:TVSDDR01 | 
                Raw signal (voltage) standard deviation of instrument output water body by 25cm path length red light transmissometer | 
             |