URI |
http://vocab.nerc.ac.uk/collection/P06/current/UPDB/2/ |
Within Vocab |
BODC-approved data storage units |
Alternative Labels |
dbar
|
Definition |
Unavailable |
Date |
2009-06-11T13:15:54 |
Identifier |
SDN:P06::UPDB |
Note |
accepted |
Is Version Of |
UPDB |
Previous Version |
1
|
version |
2 |
Same As
|
QUDT concepts
|
http://qudt.org/vocab/unit/DeciBAR |
Broader
|
P24:FORCEPAREA |
[mass]/[length]/[time*time] |
|
Related
|
P09:PRES |
SEA PRESSURE sea surface=0 |
|
| OG1:PRES |
Sea water pressure, equals 0 at sea-level |
|
| R03:PRES |
Sea water pressure, equals 0 at sea-level |
|
| P07:CFSN0330 |
sea_water_pressure |
|
| P07:CF12N583 |
sea_water_pressure_at_sea_floor |
|
| P07:CF12N584 |
sea_water_pressure_at_sea_water_surface |
|
| P07:CIEIIDJF |
sea_water_pressure_due_to_sea_water |
|
| P01:PRSTPS03 |
Pressure (measured variable sensor third sensor) exerted by the water body plus atmosphere by fixed in-situ pressure sensor |
|
| P01:PRSTPS02 |
Pressure (measured variable sensor) exerted by the water body plus atmosphere by fixed in-situ pressure sensor (second sensor) |
|
| P01:PPSSRL03 |
Pressure (measured variable third sensor) exerted by the water body by fixed in-situ pressure sensor and corrected using co-located air pressure data expressed to unspecified datum by subtraction of a constant |
|
| P01:PRESPH01 |
Pressure (measured variable) exerted by the water body by fixed half-tide pressure sensor and corrected to read zero at sea level |
|
| P01:PPSSRL02 |
Pressure (measured variable) exerted by the water body by fixed in-situ pressure sensor (second sensor) and corrected using co-located air pressure data expressed to unspecified datum by subtraction of a constant |
|
| P01:PPSSST02 |
Pressure (measured variable) exerted by the water body by fixed in-situ pressure sensor (second sensor) and drift corrected and expressed to unspecified datum by subtraction of a constant |
|
| P01:PREXPS01 |
Pressure (measured variable) exerted by the water body by fixed in-situ pressure sensor and corrected to read zero at sea level |
|
| P01:PRESPS02 |
Pressure (measured variable) exerted by the water body by fixed in-situ pressure sensor and corrected to read zero at sea level |
|
| P01:PRESPS01 |
Pressure (measured variable) exerted by the water body by fixed in-situ pressure sensor and corrected to read zero at sea level |
|
| P01:PPSSRL01 |
Pressure (measured variable) exerted by the water body by fixed in-situ pressure sensor and corrected using co-located air pressure data expressed to unspecified datum by subtraction of a constant |
|
| P01:PRSTDRAC |
Pressure (measured variable) exerted by the water body by fixed in-situ pressure sensor and correction to sea level and correction for drift |
|
| P01:PPSSST01 |
Pressure (measured variable) exerted by the water body by fixed in-situ pressure sensor and drift corrected and expressed to unspecified datum by subtraction of a constant |
|
| P01:PPSSPS04 |
Pressure (measured variable) exerted by the water body by fixed in-situ pressure sensor and expressed to unspecified datum by subtraction of a constant |
|
| P01:PPSSPS02 |
Pressure (measured variable) exerted by the water body by fixed in-situ pressure sensor and expressed to unspecified datum by subtraction of a constant |
|
| P01:PPSSPS01 |
Pressure (measured variable) exerted by the water body by fixed in-situ pressure sensor and expressed to unspecified datum by subtraction of a constant |
|
| P01:PPSSPS03 |
Pressure (measured variable) exerted by the water body by fixed in-situ pressure sensor and expressed to unspecified datum by subtraction of a constant |
|
| P01:PRESRL01 |
Pressure (measured variable) exerted by the water body by fixed in-situ pressure sensor and nominal ambient pressure value subtracted |
|
| P01:PREXISPS |
Pressure (measured variable) exerted by the water body by semi-fixed in-situ pressure sensor |
|
| P01:PREXPR01 |
Pressure (measured variable) exerted by the water body by semi-fixed in-situ pressure sensor and corrected to read zero at sea level |
|
| P01:PRCLCCL1 |
Pressure (measured variable) exerted by the water body by semi-fixed in-situ pressure sensor and corrected to read zero at sea level by laboratory calibrations |
|
| P01:PRCLCCI1 |
Pressure (measured variable) exerted by the water body by semi-fixed in-situ pressure sensor and corrected to read zero at sea level using independent measurements |
|
| P01:PREXSINT |
Pressure (measured variable) exerted by the water body by semi-fixed moored in-situ pressure sensor and interpolation between instruments with sensors |
|
| P01:PREXMCAT |
Pressure (measured variable) exerted by the water body by semi-fixed moored SBE MicroCAT |
|
| P01:PRSTPH01 |
Pressure (measured variable) exerted by the water body plus atmosphere by fixed half-tide pressure sensor |
|
| P01:PRSTDH01 |
Pressure (measured variable) exerted by the water body plus atmosphere by fixed half-tide pressure sensor and correction for drift |
|
| P01:PRSTPS01 |
Pressure (measured variable) exerted by the water body plus atmosphere by fixed in-situ pressure sensor |
|
| P01:PRSTDR01 |
Pressure (measured variable) exerted by the water body plus atmosphere by fixed in-situ pressure sensor and correction for drift |
|
| P01:PRSTDR03 |
Pressure (measured variable) exerted by the water body plus atmosphere by fixed in-situ pressure sensor and correction for drift |
|
| P01:PRSTDR02 |
Pressure (measured variable) exerted by the water body plus atmosphere by fixed in-situ pressure sensor and correction for drift |
|
| P01:PRSTPR01 |
Pressure (measured variable) exerted by the water body plus atmosphere by semi-fixed in-situ pressure sensor |
|
| P01:PRSTRSAC |
Pressure (residual) exerted by the water body by fixed in-situ pressure sensor and correction to sea level and subtraction of value predicted by tidal analysis |
|
| P01:PRSRPS01 |
Pressure (residual) exerted by the water body by fixed in-situ pressure sensor and correction using co-located air pressure and subtraction of value predicted by tidal analysis |
|
| P01:PRSTRS01 |
Pressure (residual) exerted by the water body plus atmosphere by fixed in-situ pressure sensor and subtraction of value predicted by tidal analysis |
|
| P01:PRSTRD01 |
Pressure (residual) exerted by the water body plus atmosphere by fixed in-situ pressure sensor and subtraction of value predicted by tidal analysis without correction for drift |
|
| P01:PRESCX01 |
Pressure (spatial coordinate) exerted by the water body by computation of depth using unspecified drop rate algorithm converted to pressure using UNESCO algorithm |
|
| P01:PRESPR01 |
Pressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level |
|
| P01:PRSDCT01 |
Pressure (spatial coordinate) standard deviation exerted by the water body by profiling pressure sensor |
|
| P01:PREXSTEK |
Pressure mean (measured variable) exerted by the water body by semi-fixed moored SonTek current meter |
|
| P01:SDPRSTEK |
Pressure standard deviation (measured variable) exerted by the water body by semi-fixed moored SonTek current meter |
|
|
DBpedia
|
http://dbpedia.org/resource/Bar_(unit) |