2020-05-03 20:29:08.0
SDN:R16::SECAVG
Secondary sampling: averaged
accepted
SDN:R16::SECAVG
2020-05-03 20:29:08.0
SDN:R16::SECAVG
1
Secondary sampling scheme for which the 'averaged' sampling method was used. The secondary sampling profile has N_PROF>1, and is composed of measurements that are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'averaged' sampling method refers to profiles where each data point was obtained from binned averages of multiple data measurements (pollings) from a sensor. Measurements can be taken by the Primary CTD or by auxiliary sensors.
SECAVG
1
false
Argo vertical sampling schemes
2020-05-04 03:00:04.0
VERTICAL_SAMPLING_SCHEME
British Oceanographic Data Centre
1
Argo Data Management Team
Argo vertical sampling schemes
Natural Environment Research Council
VERTICAL_SAMPLING_SCHEME
Profile sampling schemes and sampling methods. Argo netCDF variable VERTICAL_SAMPLING_SCHEME is populated by R16 altLabel.
Argo Data Management Team
Governance for vocabularies used in the Argo data system, published and maintained by the Argo Data Management Team (ADMT) and hosted on the NERC Vocabulary Server.
Near-surface sampling: averaged, unpumped
NSAVGUP
1
Near-surface sampling scheme for which the 'averaged' sampling method was used, and measurements obtained from an unpumped CTD stream. The near-surface sampling profile has N_PROF>1. It is composed of measurements focusing on the top 5 dbar of the water column, which may extend deeper so as to overlap with the primary sampling profile for the purpose of cross-calibration. These measurements are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'averaged' sampling method refers to profiles where each data point was obtained from binned averages of multiple data measurements (pollings) from a sensor. Primary sampling profiles measuring above 5 dbar should not be labelled with this sampling scheme.
1
false
SDN:R16::NSAVGUP
accepted
SDN:R16::NSAVGUP
SDN:R16::NSAVGUP
2020-05-03 20:29:08.0
2020-05-03 20:29:08.0
SDN:R16::PRMIX
SDN:R16::PRMIX
2020-05-03 20:29:08.0
Primary sampling scheme for which the 'mixed' sampling method was used. The primary sampling profile has N_PROF=1, and is composed of primary CTD measurements. The 'mixed' sampling method refers to profiles composed of data points obtained by both the 'averaged' and 'discrete' sampling methods. This sampling scheme can also be applied to measurements from auxiliary sensors obtained by the 'mixed' sampling method and taken at the same pressure levels as the Primary CTD profile. For auxiliary sensor measurements it is not required that all pressure levels contain data.
SDN:R16::PRMIX
1
accepted
1
PRMIX
false
Primary sampling: mixed
2020-05-03 20:29:08.0
NSMIXUP
accepted
2020-05-03 20:29:08.0
SDN:R16::NSMIXUP
SDN:R16::NSMIXUP
Near-surface sampling scheme for which the 'mixed' sampling method was used, and measurements obtained from an unpumped CTD stream. The near-surface sampling profile has N_PROF>1. It is composed of measurements focusing on the top 5 dbar of the water column, which may extend deeper so as to overlap with the primary sampling profile for the purpose of cross-calibration. These measurements are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'mixed' sampling method refers to profiles composed of data points obtained by both the 'averaged' and 'discrete' sampling methods. Primary sampling profiles measuring above 5 dbar should not be labelled with this sampling scheme.
2020-05-03 20:29:08.0
Near-surface sampling: mixed, unpumped
1
false
SDN:R16::NSMIXUP
1
2020-05-03 20:29:08.0
accepted
2020-05-03 20:29:08.0
BOAVE
1
1
SDN:R16::BOAVE
Bounce sampling: averaged
SDN:R16::BOAVE
SDN:R16::BOAVE
false
Bounce sampling scheme for which the 'averaged' sampling method was used. The bounce sampling scheme is composed of profiles with N_PROF>1 collected on multiple rises and falls during a single cycle. The profiles are temporally offset from each other and/or the primary sampling profile. The 'averaged' sampling method refers to profiles where each data point was obtained from binned averages of multiple data measurements (pollings) from a sensor. Bounce sampling scheme profiles can be sampled with the Primary CTD or with auxiliary sensors.
1
false
BOMIX
accepted
2020-05-03 20:29:08.0
SDN:R16::BOMIX
1
Bounce sampling scheme for which the 'mixed' sampling method was used. The bounce sampling scheme is composed of profiles with N_PROF>1 collected on multiple rises and falls during a single cycle. The profiles are temporally offset from each other and/or the primary sampling profile. The 'mixed' sampling method refers to profiles composed of data points obtained by both the 'averaged' and 'discrete' sampling methods. Bounce sampling scheme profiles can be sampled with the Primary CTD or with auxiliary sensors.
SDN:R16::BOMIX
Bounce sampling: mixed
SDN:R16::BOMIX
2020-05-03 20:29:08.0
BODIS
SDN:R16::BODIS
accepted
SDN:R16::BODIS
2020-05-03 20:29:08.0
Bounce sampling scheme for which the 'discrete' sampling method was used. The bounce sampling scheme is composed of profiles with N_PROF>1 collected on multiple rises and falls during a single cycle. The profiles are temporally offset from each other and/or the primary sampling profile. The 'discrete' sampling method refers to profiles where each data point was obtained from a single measurement (polling) from a sensor. Bounce sampling scheme profiles can be sampled with the Primary CTD or with auxiliary sensors.
1
2020-05-03 20:29:08.0
SDN:R16::BODIS
1
Bounce sampling: discrete
false
1
Near-surface sampling: averaged, pumped
SDN:R16::NSAVGP
accepted
1
2020-05-03 20:29:08.0
NSAVGP
false
Near-surface sampling scheme for which the 'averaged' sampling method was used, and measurements obtained from a pumped CTD stream. The near-surface sampling profile has N_PROF>1. It is composed of measurements focusing on the top 5 dbar of the water column, which may extend deeper so as to overlap with the primary sampling profile for the purpose of cross-calibration. These measurements are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'averaged' sampling method refers to profiles where each data point was obtained from binned averages of multiple data measurements (pollings) from a sensor. Primary sampling profiles measuring above 5 dbar should not be labelled with this sampling scheme.
SDN:R16::NSAVGP
SDN:R16::NSAVGP
2020-05-03 20:29:08.0
Secondary sampling scheme for which the 'mixed' sampling method was used. The secondary sampling profile has N_PROF>1, and is composed of measurements that are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'mixed' sampling method refers to profiles composed of data points obtained by both the 'averaged' and 'discrete' sampling methods. Measurements can be taken by the Primary CTD or by auxiliary sensors.
SDN:R16::SECMIX
SDN:R16::SECMIX
1
2020-05-03 20:29:08.0
false
Secondary sampling: mixed
2020-05-03 20:29:08.0
accepted
1
SECMIX
SDN:R16::SECMIX
Primary sampling: averaged
1
2020-05-03 20:29:08.0
SDN:R16::PRAVG
2020-05-03 20:29:08.0
Primary sampling scheme for which the 'averaged' sampling method was used. The primary sampling profile has N_PROF=1, and is composed of primary CTD measurements. The 'averaged' sampling method refers to profiles where each data point was obtained from binned averages of multiple data measurements (pollings) from a sensor. This sampling scheme can also be applied to measurements from auxiliary sensors obtained by the 'averaged' sampling method and taken at the same pressure levels as the Primary CTD profile. For auxiliary sensor measurements it is not required that all pressure levels contain data.
1
accepted
false
SDN:R16::PRAVG
SDN:R16::PRAVG
PRAVG
Near-surface sampling: mixed, pumped
NSMIXP
false
1
2020-05-03 20:29:08.0
SDN:R16::NSMIXP
SDN:R16::NSMIXP
1
Near-surface sampling scheme for which the 'mixed' sampling method was used, and measurements obtained from a pumped CTD stream. The near-surface sampling profile has N_PROF>1. It is composed of measurements focusing on the top 5 dbar of the water column, which may extend deeper so as to overlap with the primary sampling profile for the purpose of cross-calibration. These measurements are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'mixed' sampling method refers to profiles composed of data points obtained by both the 'averaged' and 'discrete' sampling methods. Primary sampling profiles measuring above 5 dbar should not be labelled with this sampling scheme.
2020-05-03 20:29:08.0
SDN:R16::NSMIXP
accepted
SDN:R16::NSDISP
Near-surface sampling scheme for which the 'discrete' sampling method was used, and measurements obtained from a pumped CTD stream. The near-surface sampling profile has N_PROF>1. It is composed of measurements focusing on the top 5 dbar of the water column, which may extend deeper so as to overlap with the primary sampling profile for the purpose of cross-calibration. These measurements are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'discrete' sampling method refers to profiles where each data point was obtained from a single measurement (polling) from a sensor. Primary sampling profiles measuring above 5 dbar should not be labelled with this sampling scheme.
2020-05-03 20:29:08.0
Near-surface sampling: discrete, pumped
1
1
accepted
SDN:R16::NSDISP
SDN:R16::NSDISP
false
2020-05-03 20:29:08.0
NSDISP
Primary sampling scheme for which the 'discrete' sampling method was used. The primary sampling profile has N_PROF=1, and is composed of primary CTD measurements. The 'discrete' sampling method refers to profiles where each data point was obtained from a single measurement (polling) from a sensor. This sampling scheme can also be applied to measurements from auxiliary sensors obtained by the 'discrete' sampling method and taken at the same pressure levels as the Primary CTD profile. For auxiliary sensor measurements it is not required that all pressure levels contain data.
1
SDN:R16::PRDIS
SDN:R16::PRDIS
Primary sampling: discrete
2020-05-03 20:29:08.0
1
accepted
false
2020-05-03 20:29:08.0
SDN:R16::PRDIS
PRDIS
SECDIS
1
SDN:R16::SECDIS
Secondary sampling: discrete
accepted
SDN:R16::SECDIS
Secondary sampling scheme for which the 'discrete' sampling method was used. The secondary sampling profile has N_PROF>1, and is composed of measurements that are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'discrete' sampling method refers to profiles where each data point was obtained from a single measurement (polling) from a sensor. Measurements can be taken by the Primary CTD or by auxiliary sensors.
false
2020-05-03 20:29:08.0
SDN:R16::SECDIS
2020-05-03 20:29:08.0
1
NSDISUP
1
accepted
Near-surface sampling: discrete, unpumped
2020-05-03 20:29:08.0
false
2020-05-03 20:29:08.0
SDN:R16::NSDISUP
1
Near-surface sampling scheme for which the 'discrete' sampling method was used, and measurements obtained from an unpumped CTD stream. The near-surface sampling profile has N_PROF>1. It is composed of measurements focusing on the top 5 dbar of the water column, which may extend deeper so as to overlap with the primary sampling profile for the purpose of cross-calibration. These measurements are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'discrete' sampling method refers to profiles where each data point was obtained from a single measurement (polling) from a sensor. Primary sampling profiles measuring above 5 dbar should not be labelled with this sampling scheme.
SDN:R16::NSDISUP
SDN:R16::NSDISUP