made by VocPrez  for NVS

Vocabulary

Argo vertical sampling schemes

Alternate Formats

Other formats for this page:

RDF/XML Turtle JSON-LD

Alternate Profiles

Other views of this page:

Alternate Profiles ?Different Media Types (HTML, text, RDF, JSON etc.) and different information model views, profiles, are available for this resource.

Members

ID Preferred Label Definition Date
BOAVE Bounce sampling: averaged Bounce sampling scheme for which the 'averaged' sampling method was used. The bounce sampling scheme is composed of profiles with N_ PROF>1 collected on multiple rises and falls during a single cycle. The profiles are temporally offset from each other and/or the primary sampling profile. The 'averaged' sampling method refers to profiles where each data point was obtained from binned averages of multiple data measurements (pollings) from a sensor. Bounce sampling scheme profiles can be sampled with the Primary CTD or with auxiliary sensors. 2020-05-03
BODIS Bounce sampling: discrete Bounce sampling scheme for which the 'discrete' sampling method was used. The bounce sampling scheme is composed of profiles with N_ PROF>1 collected on multiple rises and falls during a single cycle. The profiles are temporally offset from each other and/or the primary sampling profile. The 'discrete' sampling method refers to profiles where each data point was obtained from a single measurement (polling) from a sensor. Bounce sampling scheme profiles can be sampled with the Primary CTD or with auxiliary sensors. 2020-05-03
BOMIX Bounce sampling: mixed Bounce sampling scheme for which the 'mixed' sampling method was used. The bounce sampling scheme is composed of profiles with N_ PROF>1 collected on multiple rises and falls during a single cycle. The profiles are temporally offset from each other and/or the primary sampling profile. The 'mixed' sampling method refers to profiles composed of data points obtained by both the 'averaged' and 'discrete' sampling methods. Bounce sampling scheme profiles can be sampled with the Primary CTD or with auxiliary sensors. 2020-05-03
NSAVGP Near-surface sampling: averaged, pumped Near-surface sampling scheme for which the 'averaged' sampling method was used, and measurements obtained from a pumped CTD stream. The near-surface sampling profile has N_ PROF>1. It is composed of measurements focusing on the top 5 dbar of the water column, which may extend deeper so as to overlap with the primary sampling profile for the purpose of cross-calibration. These measurements are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'averaged' sampling method refers to profiles where each data point was obtained from binned averages of multiple data measurements (pollings) from a sensor. Primary sampling profiles measuring above 5 dbar should not be labelled with this sampling scheme. 2020-05-03
NSAVGUP Near-surface sampling: averaged, unpumped Near-surface sampling scheme for which the 'averaged' sampling method was used, and measurements obtained from an unpumped CTD stream. The near-surface sampling profile has N_ PROF>1. It is composed of measurements focusing on the top 5 dbar of the water column, which may extend deeper so as to overlap with the primary sampling profile for the purpose of cross-calibration. These measurements are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'averaged' sampling method refers to profiles where each data point was obtained from binned averages of multiple data measurements (pollings) from a sensor. Primary sampling profiles measuring above 5 dbar should not be labelled with this sampling scheme. 2020-05-03
NSDISP Near-surface sampling: discrete, pumped Near-surface sampling scheme for which the 'discrete' sampling method was used, and measurements obtained from a pumped CTD stream. The near-surface sampling profile has N_ PROF>1. It is composed of measurements focusing on the top 5 dbar of the water column, which may extend deeper so as to overlap with the primary sampling profile for the purpose of cross-calibration. These measurements are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'discrete' sampling method refers to profiles where each data point was obtained from a single measurement (polling) from a sensor. Primary sampling profiles measuring above 5 dbar should not be labelled with this sampling scheme. 2020-05-03
NSDISUP Near-surface sampling: discrete, unpumped Near-surface sampling scheme for which the 'discrete' sampling method was used, and measurements obtained from an unpumped CTD stream. The near-surface sampling profile has N_ PROF>1. It is composed of measurements focusing on the top 5 dbar of the water column, which may extend deeper so as to overlap with the primary sampling profile for the purpose of cross-calibration. These measurements are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'discrete' sampling method refers to profiles where each data point was obtained from a single measurement (polling) from a sensor. Primary sampling profiles measuring above 5 dbar should not be labelled with this sampling scheme. 2020-05-03
NSMIXP Near-surface sampling: mixed, pumped Near-surface sampling scheme for which the 'mixed' sampling method was used, and measurements obtained from a pumped CTD stream. The near-surface sampling profile has N_ PROF>1. It is composed of measurements focusing on the top 5 dbar of the water column, which may extend deeper so as to overlap with the primary sampling profile for the purpose of cross-calibration. These measurements are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'mixed' sampling method refers to profiles composed of data points obtained by both the 'averaged' and 'discrete' sampling methods. Primary sampling profiles measuring above 5 dbar should not be labelled with this sampling scheme. 2020-05-03
NSMIXUP Near-surface sampling: mixed, unpumped Near-surface sampling scheme for which the 'mixed' sampling method was used, and measurements obtained from an unpumped CTD stream. The near-surface sampling profile has N_ PROF>1. It is composed of measurements focusing on the top 5 dbar of the water column, which may extend deeper so as to overlap with the primary sampling profile for the purpose of cross-calibration. These measurements are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'mixed' sampling method refers to profiles composed of data points obtained by both the 'averaged' and 'discrete' sampling methods. Primary sampling profiles measuring above 5 dbar should not be labelled with this sampling scheme. 2020-05-03
PRAVG Primary sampling: averaged Primary sampling scheme for which the 'averaged' sampling method was used. The primary sampling profile has N_ PROF=1, and is composed of primary CTD measurements. The 'averaged' sampling method refers to profiles where each data point was obtained from binned averages of multiple data measurements (pollings) from a sensor. This sampling scheme can also be applied to measurements from auxiliary sensors obtained by the 'averaged' sampling method and taken at the same pressure levels as the Primary CTD profile. For auxiliary sensor measurements it is not required that all pressure levels contain data. 2020-05-03
PRDIS Primary sampling: discrete Primary sampling scheme for which the 'discrete' sampling method was used. The primary sampling profile has N_ PROF=1, and is composed of primary CTD measurements. The 'discrete' sampling method refers to profiles where each data point was obtained from a single measurement (polling) from a sensor. This sampling scheme can also be applied to measurements from auxiliary sensors obtained by the 'discrete' sampling method and taken at the same pressure levels as the Primary CTD profile. For auxiliary sensor measurements it is not required that all pressure levels contain data. 2020-05-03
PRMIX Primary sampling: mixed Primary sampling scheme for which the 'mixed' sampling method was used. The primary sampling profile has N_ PROF=1, and is composed of primary CTD measurements. The 'mixed' sampling method refers to profiles composed of data points obtained by both the 'averaged' and 'discrete' sampling methods. This sampling scheme can also be applied to measurements from auxiliary sensors obtained by the 'mixed' sampling method and taken at the same pressure levels as the Primary CTD profile. For auxiliary sensor measurements it is not required that all pressure levels contain data. 2020-05-03
SECAVG Secondary sampling: averaged Secondary sampling scheme for which the 'averaged' sampling method was used. The secondary sampling profile has N_ PROF>1, and is composed of measurements that are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'averaged' sampling method refers to profiles where each data point was obtained from binned averages of multiple data measurements (pollings) from a sensor. Measurements can be taken by the Primary CTD or by auxiliary sensors. 2020-05-03
SECDIS Secondary sampling: discrete Secondary sampling scheme for which the 'discrete' sampling method was used. The secondary sampling profile has N_ PROF>1, and is composed of measurements that are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'discrete' sampling method refers to profiles where each data point was obtained from a single measurement (polling) from a sensor. Measurements can be taken by the Primary CTD or by auxiliary sensors. 2020-05-03
SECMIX Secondary sampling: mixed Secondary sampling scheme for which the 'mixed' sampling method was used. The secondary sampling profile has N_ PROF>1, and is composed of measurements that are taken at pressure levels different from the primary sampling profile, or obtained by a sampling method different from that of the primary sampling profile. The 'mixed' sampling method refers to profiles composed of data points obtained by both the 'averaged' and 'discrete' sampling methods. Measurements can be taken by the Primary CTD or by auxiliary sensors. 2020-05-03